Alloy Computer Products GSS-24T4SFP Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Netzwerk-Switches Alloy Computer Products GSS-24T4SFP herunter. Alloy Computer Products GSS-24T4SFP User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 54
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
GSS Series User Manual
User Manual
GSS Series
16/24 Port Gigabit Web
Managed Switch
(GSS-16T4SFP & GSS-24T4SFP)
Version 1.0
Sep. 2007
Alloy Computer Products Pty Ltd Copyright ©2007
1
Seitenansicht 0
1 2 3 4 5 6 ... 53 54

Inhaltsverzeichnis

Seite 1 - User Manual

GSS Series User Manual User Manual GSS Series 16/24 Port Gigabit Web Managed Switch (GSS-16T4SFP & GSS-24T4SFP) Version 1.0 Sep. 2007 Allo

Seite 2 - Table of Contents

GSS Series User Manual 2. Installation 2.1. Starting the GSS Series Switches This section provides a quick start guide for: • Hardware and Cable I

Seite 3

GSS Series User Manual • Copper Ports - Cable Installation Please Note: ⇒ The RJ-45 ports on the GSS Series Gigabit Switches support MDI/MDI-X auto-

Seite 4

GSS Series User Manual 2.1.2. Cabling Requirements To help ensure a successful installation and keep network performance at optimum levels, take care

Seite 5 - 1. Introduction

GSS Series User Manual Cont. Please Note: ⇒ Further information can be found in section 1.5 on page 7 ⇒ All figures denoting the range a given cable

Seite 6

GSS Series User Manual 3. Operation of the Web Based Management The following chapter allows the administrator to monitor and manage the GSS series t

Seite 7

GSS Series User Manual 3.1 Web Management Home Overview Once you have entered a valid password and logged into the switch the System Configuration pa

Seite 8

GSS Series User Manual 3.2 Configuration 3.2.1 System Information The System Information configuration page is used to display basic switch informati

Seite 9 - Alloy Part No. Description

GSS Series User Manual Management VLAN: Enter the VLAN group used to gain access to the web management. Default value is 1. If you change this value

Seite 10 - 2. Installation

GSS Series User Manual 3.2.2 Ports The ports configuration page is used to display the current status of each port on the switch. In this section the

Seite 11 - GSS Series User Manual

GSS Series User Manual Drop Frames after Excessive Collisions: Used when running half duplex equipment, tick the check box to enable this feature. Ap

Seite 12

GSS Series User Manual Table of Contents CAUTION ...

Seite 13

GSS Series User Manual 3.2.3 VLAN Mode The GSS Series of switches support port based VLAN’s, 802.1q tagged VLAN’s and Metro mode VLAN’s. Up to 16 acti

Seite 14

GSS Series User Manual Metro-Mode: Metro Mode VLAN’s is a quick method of creating 13, 14, 15 or 16 port based VLAN groups. Each port is separated in

Seite 15

GSS Series User Manual 3.2.4 VLAN Group Tag Based VLAN’s Fig. 3.5 VLAN ID: To create a new VLAN group, Enter a valid VLAN ID into the space provide

Seite 16 - 3.2 Configuration

GSS Series User Manual Apply Button: The Apply button must be pressed after making any changes to any of the values on this screen. Port Config: Use

Seite 17

GSS Series User Manual Fig. 3.8 Modify: Select the radio button next to the VLAN you wish to modify and click modify. Delete: Select the radio butt

Seite 18

GSS Series User Manual Port Based VLAN’s Fig. 3.9 VLAN ID: To create a new VLAN group, Enter a valid VLAN ID into the space provided. A new screen

Seite 19

GSS Series User Manual Apply Button: The Apply button must be pressed after making any changes to any of the values on this screen. Fig. 3.11 Modify

Seite 20

GSS Series User Manual Metro Mode VLAN’s Fig. 3.12 Uplink Port: Select the port(s) that you wish to use as your uplink port(s). This is the port(s)

Seite 21

GSS Series User Manual 3.2.5 Aggregation Port Aggregation is used to Aggregate Ports into a logical trunk usually called Link Aggregation. Link Aggreg

Seite 22

GSS Series User Manual 3.2.6 LACP Link Aggregation Control Protocol is a protocol used to dynamically trunk ports into groups that have the same LACP

Seite 23

GSS Series User Manual Caution Electronic Circuit devices are sensitive to static electricity. Dry weather conditions or walking across a carpeted fl

Seite 24

GSS Series User Manual 3.2.7 RSTP The Spanning Tree Protocol is an IEEE 802.1d standard designed for avoiding unwanted loops in switched networks. Whe

Seite 25

GSS Series User Manual Protocol Enabled: Used to enable the Rapid Spanning Tree Protocol on individual ports. Edge: Edge will be enabled if the port

Seite 26

GSS Series User Manual 3.2.8 802.1x The 802.1x port-based network access control provides a method to restrict users to access network resources via a

Seite 27

GSS Series User Manual Action: Re-authenticate forces the port to re-authenticate with the RADIUS server. Force Re-initialise forces the port to re-i

Seite 28

GSS Series User Manual 802.1x Parameters Fig. 3.18 Re-authentication Enabled: Tick the checkbox to force re-authentication between the port and the

Seite 29

GSS Series User Manual 3.2.9 IGMP IGMP Snooping is used to establish multicast groups to forward multicast packets to each of the multicast member por

Seite 30

GSS Series User Manual 3.2.10 Port Mirroring The Mirror function of the GSS Series is used to capture data from a particular port on the switch. Any p

Seite 31

GSS Series User Manual 3.2.11 Quality of Service Two methods of Quality of Service is available in the GSS Series, they are 802.1p QoS – Is a tag base

Seite 32

GSS Series User Manual 3.2.11.2 Quality of Service – DSCP Fig. 3.22 QoS Mode: Used to set the required QoS method. Options are 802.1p and DSCP. Prio

Seite 33

GSS Series User Manual 3.2.12 Filter The filtering function of the GSS Series is used to block unwanted devices from accessing the switch. The filteri

Seite 34

GSS Series User Manual About this User Manual This User Manual will guide you on procedures to install, configure and monitor Alloy 16 port Gigabit

Seite 35

GSS Series User Manual 3.2.13 Rate Limit The Rate Limit function of the GSS Series is used to limit the speed of each port on the switch. Fig. 3.24

Seite 36

GSS Series User Manual 3.2.14 Storm Control Storm Control is used to limit the amount of Broadcast, Multicast and Unicast frames allowed to enter the

Seite 37

GSS Series User Manual 3.2.15 SNMP Fig. 3.26 SNMP Enabled: Used to enable or disable SNMP. SNMP Trap Destination: Enter the IP address of a devic

Seite 38

GSS Series User Manual 3.3 Monitoring 3.3.1 Detailed Statistics The detailed port statistics screen shows you in detail statistics of each individual

Seite 39

GSS Series User Manual 3.3.2 LACP Status Displays the status of all LACP based port aggregation groups. Fig. 3.28 Refresh Button: Used to refresh th

Seite 40

GSS Series User Manual 3.3.3 RSTP Status Displays the current status of RSTP. Fig. 3.29 Refresh Button: Used to refresh the current settings display

Seite 41

GSS Series User Manual 3.3.4 IGMP Status Displays the current status of multicast groups learnt by the switch. Fig. 3.30 Refresh Button: Used to ref

Seite 42

GSS Series User Manual 3.3.5 Ping The ping function of the switch is used to test communication between other IP enabled devices on your network. Fig

Seite 43 - 3.3 Monitoring

GSS Series User Manual 3.4 Maintenance 3.4.1 Warm Restart Fig. 3.32 Click Yes to reboot the device or No to cancel the operation. A

Seite 44

GSS Series User Manual 3.4.2 Factory Default Fig. 3.33 Click Yes to restore the factory default settings on the switch, or No to cancel the operation

Seite 45

GSS Series User Manual 1. Introduction 1.1 Overview Alloy 16/24 Port Gigabit Switches meet all IEEE 802.3/u/x/z standards Gigabit and Fast Ethernet sp

Seite 46

GSS Series User Manual 3.4.3 Software Upgrade Fig. 3.34 Browse: Used to select the firmware file to load into the switch. Upload: Once the file has

Seite 47

GSS Series User Manual 3.4.4 Configuration File Transfer The GSS Series allows the user to backup and restore the configuration settings of the switch

Seite 48 - 3.4 Maintenance

GSS Series User Manual 3.4.5 Logout Press the logout button to logout of the web management. Alloy Computer Products Pty Ltd Copyright ©2007 5

Seite 49

GSS Series User Manual Appendix A – Technical Specifications Hardware Specifications  Standard Compliance: IEEE802.3/802.3ab / 802.3z / 802.3u /

Seite 50

GSS Series User Manual  Diagnostic LED: System LED : Power Per Port LED: 10/100/1000M TP Port 1 to 12 : LINK/ACT, 10/100/1000Mbps

Seite 51

GSS Series User Manual 1.2 Key Features • 16 or 24 10/100/1000Mbps Gigabit Ethernet Ports all compliant with IEEE802.3, 802.3u, 802.3z and 802.3ab •

Seite 52

GSS Series User Manual 1.4.1 User interfaces on the front panel The front panel of the GSS-16T4SFP and GSS-24T4SFP consists of 16x or 24x 10/100/1000

Seite 53

GSS Series User Manual LED Indicators LED COLOUR FUNCTION System LED’s Power Green Lit when Power is active Gigabit Copper Ports Link/Act Green

Seite 54

GSS Series User Manual 1.5. Overview of the Optional SFP Modules With the GSS-16T4SFP switch, the SFP ports are paired with RJ-45 copper ports 13, 14,

Kommentare zu diesen Handbüchern

Keine Kommentare